{"id":1620,"date":"2023-10-18T13:08:47","date_gmt":"2023-10-18T11:08:47","guid":{"rendered":"https:\/\/cncgraf.com\/?p=1620"},"modified":"2023-12-20T21:45:28","modified_gmt":"2023-12-20T20:45:28","slug":"setting-the-spindle-speed","status":"publish","type":"post","link":"https:\/\/cncgraf.com\/en\/2023\/10\/18\/einrichtung-der-spindeldrehzahl\/","title":{"rendered":"Setting the spindle speed for the CNC machine"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-tertiary-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-left has-tertiary-background-color has-background has-large-font-size translation-block\" id=\"einrichtung-und-verwenden-der-spindeldrehzahl-fur-die-cnc-maschine\">Setting up and using the spindle speed <br>for the CNC machine<\/h1>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">In this article, I will describe how to connect and test the hardware for the spindle speed. <br>I will also explain how the speed can be activated and used using the <a href=\"https:\/\/cncgraf.com\/en\/cncgraf-8-cnc-steuerungssoftware\/\" data-type=\"page\" data-id=\"8\" target=\"_self\">cncGraF<\/a> software. <br><br>Before we start setting up the speed, however, we first need to clarify which hardware components are required to use the speed.<\/p>\n\n\n\n<hr class=\"wp-block-separator alignfull has-text-color has-cyan-bluish-gray-color has-alpha-channel-opacity has-cyan-bluish-gray-background-color has-background\"\/>\n<\/div>\n\n\n\n<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h4>Overview<\/h4><nav><ul><li class=\"\"><a href=\"#1-was-benotige-ich-fur-die-spindeldrehzahl-steuerung\">1. what do I need for the spindle speed control?<\/a><\/li><li class=\"\"><a href=\"#2-einrichtung-hardware-anschliessen\">2. setup: connect hardware<\/a><\/li><li class=\"\"><a href=\"#3-einrichtung-software-einstellen\">3. set-up: setting up the software<\/a><\/li><li class=\"\"><a href=\"#4-spindeldrehzahl-testen\">4. test spindle speed<\/a><\/li><li class=\"\"><a href=\"#5-fehlersuche\">5. troubleshooting<\/a><\/li><li class=\"\"><a href=\"#6-verwendung\">6. use<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-base-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"1-was-benotige-ich-fur-die-spindeldrehzahl-steuerung\">1. what do I need for the spindle speed control?<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"translation-block\"><strong>Frequency inverter with matching spindle motor:<\/strong> A frequency inverter, also known as an inverter or frequency converter, is an electronic device that changes the frequency and voltage. It is required to control the speed of the spindle.<\/li>\n\n\n\n<li class=\"translation-block\"><strong>Interface card <a href=\"https:\/\/web.boenigk-electronics.com\/download\/docs\/relais\/dac-int-10V-v3.pdf\" target=\"_self\">DAC-INT-10V<\/a> or <a href=\"https:\/\/web.boenigk-electronics.com\/download\/docs\/smc5dm4\/smc5d_m4_system.pdf\" target=\"_self\">CAN Expansion DAC 0-10V<\/a>:<\/strong> These cards have an analogue output in the range of 0-10 volts as well as a switching signal. Both connections are required to transmit the corresponding control commands to the frequency inverter.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"2-einrichtung-hardware-anschliessen\">2. setup: connect hardware<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The first step is to install the interface card. <\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">The DAC-INT-10V interface card is required for the smc5d-p32 or smc5d-m4 lan CNC controller, <br>while the control cabinet version CAN Expansion DAC 0-10V is required for the smc5d-m4 pro.<\/p>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>The DAC-INT-10V interface card for CNC controllers smc5d-p32 and smc5d-m4 lan<br><\/summary>\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">The DAC-INT-10V interface card is plugged into the CNC controller, either the smc5d-p32 or the smc5d-m4 lan.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-int10v_auf_controller_drauf.jpg\" alt=\"\" class=\"wp-image-1694\"\/><figcaption class=\"wp-element-caption\">The picture shows the DAC-INT-10V interface card, which is plugged into the smc5d-p32 CNC controller.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">The DAC-INT-10V interface card can be supplied with +24 volts in two different ways: via the external connection (green connection) or via the pins on CON3 (ribbon cable). The variant via CON3 is usually used together with a relay card, where the +24 volts come from the relay card.<br><br><img width=\"24\" height=\"24\" class=\"wp-image-1775\" style=\"width: 24px\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/info.png\" alt=\"\"> <strong>Note:<\/strong> The +24 volt power supply is required for the 0-10 volt analogue output.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The DAC-INT-10V interface card can also be supplied with 5 volts. The 5 volts are used to supply the CNC controller with power externally (not via the USB interface).<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"1211\" height=\"428\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-ont10v-24plus.jpg\" alt=\"\" class=\"wp-image-1697\" style=\"width:908px;height:321px\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-ont10v-24plus.jpg 1211w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-ont10v-24plus-600x212.jpg 600w\" sizes=\"(max-width: 1211px) 100vw, 1211px\" \/><figcaption class=\"wp-element-caption translation-block\">The DAC-INT-10V interface card is powered via an external connection (power supply) <br>or via the pins on CON3<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"1103\" height=\"586\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dac-ont10v-24plus2.jpg\" alt=\"\" class=\"wp-image-1948\" style=\"width:827px;height:440px\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dac-ont10v-24plus2.jpg 1103w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dac-ont10v-24plus2-600x319.jpg 600w\" sizes=\"(max-width: 1103px) 100vw, 1103px\" \/><figcaption class=\"wp-element-caption\">Power supply via a ribbon cable and an external relay card<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, the frequency inverter must be supplied with 0-10 volts and a switching signal. The connections in the corner of the DAC-INT-10V interface card are used for this purpose. <br><br>The switching signal: The two connections Rel1 and Rel1 connect the plugged cables, whereby the connection is only made when output 1 for the spindle is switched in the cncGraF software.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"1412\" height=\"749\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-int10v-freq.jpg\" alt=\"\" class=\"wp-image-1719\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-int10v-freq.jpg 1412w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac-int10v-freq-600x318.jpg 600w\" sizes=\"(max-width: 1412px) 100vw, 1412px\" \/><figcaption class=\"wp-element-caption\">The connections for the frequency inverter can be found in the corner of the DAC-INT-10V interface card.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">This completes the hardware connection. The spindle speed can now be switched on and tested in the cncGraF software. Make sure that all connections are correct and secure before carrying out the test.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-f96fecc4 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/web.boenigk-electronics.com\/download\/docs\/dac-int-10v\/dac_int_10V_v3b.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" width=\"51\" height=\"51\" fetchpriority=\"low\" class=\"wp-image-1147\" style=\"width: 51px;\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/pdf.png\" alt=\"\"> Download - Documentation<\/a><\/div>\n\n\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>The CAN Expansion DAC 0-10V expansion card<br><\/summary>\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">The CAN Expansion DAC 0-10V expansion card is required when using the smc5d-m4 pro CNC controller for top-hat rail mounting. It is connected via a CAN cable supplied. The +24 V power supply is provided via the green connection at the bottom left (see image below).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The switching signal: The two Rel_A connections connect the plugged cables, whereby the connection is only made when output 1 for the spindle is switched in the cncGraF software.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"929\" height=\"1024\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-929x1024.png\" alt=\"\" class=\"wp-image-527\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-929x1024.png 929w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-600x661.png 600w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-272x300.png 272w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-768x846.png 768w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-1394x1536.png 1394w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/dac_gimp-1859x2048.png 1859w\" sizes=\"(max-width: 929px) 100vw, 929px\" \/><figcaption class=\"wp-element-caption\">CAN Expansion DAC 0-10V is the expansion card for top-hat rail CNC controller smc5d-m4 pro and for spindle speed control<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">This completes the hardware connection. The spindle speed can now be switched on and tested in the cncGraF software. Make sure that all connections are correct and secure before carrying out the test.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"http:\/\/web.boenigk-electronics.com\/download\/docs\/smc5dm4\/smc5d_m4_system.pdf\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" width=\"51\" height=\"51\" fetchpriority=\"low\" class=\"wp-image-1147\" style=\"width: 51px;\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/05\/pdf.png\" alt=\"\"> Download -Documentation<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/details>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"3-einrichtung-software-einstellen\">3. set-up: setting up the software<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The spindle speed is activated in cncGraF in the tool storage menu (see image below). You can access this function either via the main menu \u201eSettings -&gt; Tool storage\u201c or by simply clicking on the tool storage symbol.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"899\" height=\"88\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_offnen.jpg\" alt=\"\" class=\"wp-image-1742\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_offnen.jpg 899w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_offnen-600x59.jpg 600w\" sizes=\"auto, (max-width: 899px) 100vw, 899px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Click on the \u201eGlobal settings\u201c tab in the Tool store dialogue. The spindle speed function can be found there. Click on the \u201eUse spindle speed\u201c checkbox to activate the spindle speed. Next to the checkbox you will find the \u201eSet spindle speed\u201c button. Click on this button to open the dialogue window for setting the spindle speed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"818\" height=\"381\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_spindeldrehzahl.jpg\" alt=\"\" class=\"wp-image-1744\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_spindeldrehzahl.jpg 818w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/werkzeuglager_spindeldrehzahl-600x279.jpg 600w\" sizes=\"auto, (max-width: 818px) 100vw, 818px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The dialogue window \u201eDefinition of steps for spindle speed\u201c appears. Set your speed range there, starting with the lowest speed 0. In the image below, the speed range is set from 0 to 25000. Please refer to the operating instructions for your spindle for your speed range. Please note that the range is set in the AD0 tab. The AD1 and AD2 tabs are intended for other analogue outputs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The \u201eInterface DAC-INT-10V v.02\u201c checkbox should remain ticked. This option should only be unchecked if you have an older version than v.02. The older interface cards were imprecise in the 0-10 volt range. Not activating the checkbox activates an algorithm that compensates for this inaccuracy.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"840\" height=\"479\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dialog_Spindeldrehzahl.jpg\" alt=\"\" class=\"wp-image-1749\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dialog_Spindeldrehzahl.jpg 840w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/dialog_Spindeldrehzahl-600x342.jpg 600w\" sizes=\"auto, (max-width: 840px) 100vw, 840px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The settings for the speed control have been finalised. The first test can now be carried out.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"4-spindeldrehzahl-testen\">4. test spindle speed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph translation-block\">The spindle speed can now be tested. To do this, perform the test in the \u201eManual movement\u201c window, which is normally docked on the right. If this window is not visible, you can display it in the main menu by selecting \u201eWindow -&gt; Move manually\u201c.<br><br>In the \u201eMove manually\u201c window, you will find the \u201eSpindle speed\u201c button. However, first click on the \u201eSpindle\u201c button to switch on the spindle and then on the \u201eSpindle speed\u201c button. The dialogue window for the spindle speed then appears. In this dialogue window, you can change the speed by clicking and holding on the graphic. The spindle speed is adjusted accordingly.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1149\" height=\"507\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/10\/spindeldrehzahl_testen2.jpg\" alt=\"\" class=\"wp-image-2931\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/10\/spindeldrehzahl_testen2.jpg 1149w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/10\/spindeldrehzahl_testen2-600x265.jpg 600w\" sizes=\"auto, (max-width: 1149px) 100vw, 1149px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph translation-block\"><img width=\"24\" height=\"24\" class=\"wp-image-1775\" style=\"width: 24px\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/info.png\" alt=\"\"> <strong><mark class=\"has-inline-color has-custom-hintergrund-1-b-5-e-3-ff-color\">Hinweis:<\/mark><\/strong> Da das \u201eManuell Bewegen\u201c-Fenster individuell anpassbar ist, k\u00f6nnte es sein, dass dieser Button nicht vorhanden ist. In diesem Fall m\u00fcssen Sie den Button f\u00fcr die Spindeldrehzahl einblenden lassen. Gehen Sie dazu mit der Maus in das \u201eManuell Bewegen\u201c-Fenster irgendwo zwischen die Elemente und klicken Sie die rechte Maustaste, um das Kontextmen\u00fc aufzurufen. W\u00e4hlen Sie \u201eCustomize Layout\u201c aus. In dem Dialog \u201eLayout Customization\u201c suchen Sie nach dem Button \u201eSpindle Speed Button\u201c und ziehen Sie diesen per Drag-and-Drop in das \u201eManuell Bewegen\u201c-Fenster ein.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"5-fehlersuche\">5. troubleshooting<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If the speed does not work, the following points should be checked:<\/p>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Check the +24 volt power supply for the interface card<br><\/summary>\n<p class=\"wp-block-paragraph\">This can be checked with a voltmeter. All you need to do is measure the DC voltage at pins 3 and 4 (see image below). During the measurement process, the spindle speed must of course be adjusted in the software at the same time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"807\" fetchpriority=\"low\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac_testen.jpg\" alt=\"\" class=\"wp-image-1855\" srcset=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac_testen.jpg 1024w, https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/07\/dac_testen-600x473.jpg 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Check the switching signal (output 1) for spindle switching<br><\/summary>\n<p class=\"wp-block-paragraph\">To do this, the setting for the spindle must be checked in the \u201aMachine parameters -&gt; Pin assignment\u2018 menu. The spindle must have output 1 for the DAC-INT-10V interface card. When the spindle is switched (output 1), a red diode lights up on the DAC-INT-10V.<\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/details>\n\n\n\n<p class=\"wp-block-paragraph translation-block\"><img width=\"24\" height=\"24\" class=\"wp-image-1775\" style=\"width: 24px\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/info.png\" alt=\"\"> <strong>Hinweis:<\/strong> Der h\u00e4ufigste Fehler ist die fehlende Stromversorgung von +24 Volt.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left has-large-font-size\" id=\"6-verwendung\">6. use<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The spindle speed setting in the cncGraF software varies depending on the file type. <br><br>For 2D file formats such as DXF or HPGL, the spindle speed is set in the \u201eTool storage\u201c dialogue. This is because DXF and HPGL files do not have the command for the spindle speed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">G-code files, on the other hand, contain an \u201aS\u2018 command for the spindle speed. The speed is therefore taken from the G-code file. The setting for the speed in G-code files is then made in your CAD\/CAM software.<\/p>\n\n\n\n<p class=\"wp-block-paragraph translation-block\"><img width=\"24\" height=\"24\" class=\"wp-image-1775\" style=\"width: 24px\" src=\"https:\/\/cncgraf.com\/wp-content\/uploads\/2023\/08\/info.png\" alt=\"\"> <strong>Note:<\/strong> Preheating the spindle of the CNC machine reduces the load on its components. This means that the spindle can last longer and is less susceptible to repairs.<br>In this video, I show how to set up the \u201eSpindle warm-up\u201c function for CNC machines in cncGraF 8.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-f56f613f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"default\" data-borlabs-cookie-content=\"PGlmcmFtZSB3aWR0aD0iNTYwIiBoZWlnaHQ9IjMxNSIgc3JjPSJodHRwczovL3d3dy55b3V0dWJlLW5vY29va2llLmNvbS9lbWJlZC9fWXlCRTBGN0c1byIgdGl0bGU9IllvdVR1YmUgdmlkZW8gcGxheWVyIiBmcmFtZWJvcmRlcj0iMCIgYWxsb3c9ImFjY2VsZXJvbWV0ZXI7IGF1dG9wbGF5OyBjbGlwYm9hcmQtd3JpdGU7IGVuY3J5cHRlZC1tZWRpYTsgZ3lyb3Njb3BlOyBwaWN0dXJlLWluLXBpY3R1cmU7IHdlYi1zaGFyZSIgYWxsb3dmdWxsc2NyZWVuPjwvaWZyYW1lPg==\"><div class=\"brlbs-cmpnt-cb-preset-a\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing placeholder content from <strong>Default<\/strong>. To access the actual content, please click the button below. Please note that doing so will share data with third-party providers.<\/p> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: none\">Accept required service and unblock content<\/a> <\/div> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">Further information<\/a> <\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"default\" data-borlabs-cookie-content=\"PGlmcmFtZSB3aWR0aD0iNTYwIiBoZWlnaHQ9IjMxNSIgc3JjPSJodHRwczovL3d3dy55b3V0dWJlLW5vY29va2llLmNvbS9lbWJlZC9DM0NMNm1zYUNQST9zaT1jT1BSN280M3ZqZ0Q0d1dVIiB0aXRsZT0iWW91VHViZSB2aWRlbyBwbGF5ZXIiIGZyYW1lYm9yZGVyPSIwIiBhbGxvdz0iYWNjZWxlcm9tZXRlcjsgYXV0b3BsYXk7IGNsaXBib2FyZC13cml0ZTsgZW5jcnlwdGVkLW1lZGlhOyBneXJvc2NvcGU7IHBpY3R1cmUtaW4tcGljdHVyZTsgd2ViLXNoYXJlIiBhbGxvd2Z1bGxzY3JlZW4+PC9pZnJhbWU+\"><div class=\"brlbs-cmpnt-cb-preset-a\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing placeholder content from <strong>Default<\/strong>. To access the actual content, please click the button below. Please note that doing so will share data with third-party providers.<\/p> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: none\">Accept required service and unblock content<\/a> <\/div> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">Further information<\/a> <\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">We hope that this article has been helpful to you in handling the spindle speed. If you have any questions, please do not hesitate to contact us.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yours sincerely, Your BOENIGK-electronics Team<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>In the following article, I will show you how to set up the spindle speed. First, the hardware, i.e. the frequency inverter with the interface card and the controller, is connected together. Then we make the spindle speed settings in the cncGraF software.<\/p>","protected":false},"author":1,"featured_media":1694,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[6,5,8,9,7],"class_list":["post-1620","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-allgemein","tag-dac-int-10v","tag-frequenzumrichter","tag-spindel","tag-spindel-warmlaufen","tag-spindeldrehzahl"],"_links":{"self":[{"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/posts\/1620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/comments?post=1620"}],"version-history":[{"count":0,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/posts\/1620\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/media\/1694"}],"wp:attachment":[{"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/media?parent=1620"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/categories?post=1620"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cncgraf.com\/en\/wp-json\/wp\/v2\/tags?post=1620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}